ZIP 77069 Tap Water Quality Report
What the State of Texas found in the water utilities serving 77069 in Houston, TX, and how to treat it.
Found Above EPA Health Goals
An EPA health goal is the level at which no health risk is expected. Legal limits are often higher, because they also weigh the cost of treatment. These contaminants were found above the health goal in at least one utility serving 77069.
Source: Test results from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, samples collected October 2023 through October 2026. Health goals and legal limits from the U.S. EPA National Primary Drinking Water Regulations. Each utility below lists its state water system ID so you can look up its records.
Results by Water Utility
Your water utility is the name on your water bill. Open it to see everything the state found in its water from October 2023 through October 2026.
City of Houston Willow Chase serves about 13,254 people · hardness 9.9 gpg (hard) · 6 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 2.2 ppb | 2.5 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.1 ppb | 6.1 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 4.5 ppb | 7.6 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 3 pCi/L | 3 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 0.28 ppb | 0.83 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Uranium Above health goal A naturally radioactive metal in Texas groundwater. | 2.8 ppb | 2.8 ppb | 30 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.24 ppm | 0.28 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 51.7 ppm | 56 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 2.4 ppb | 2.4 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.024 ppm | 0.081 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.4 ppb | 1.4 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 3.2 ppb | 11 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.13 ppm | 0.13 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 1.4 ppb | 1.4 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.042 ppm | 0.042 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0028 ppm | 0.0028 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.6 ppb | 1.8 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.26 ppm | 0.37 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Selenium A natural mineral that is harmful at high levels. | 4.5 ppb | 5.5 ppb | 50 ppb | 50 ppb | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 25.3 ppm | 27.3 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 6 ppm | 6 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 288 ppm | 303 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 4.7 ppb | 12.7 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.01 ppm | 0.01 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Di(2-Ethylhexyl) Phthalate, Gross Alpha, Incl. Radon & U, Texas Lead.
Source: TCEQ Drinking Water Viewer, public water system ID TX1011902. 129 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1011902.
Cypress Forest Public Utility District serves about 7,356 people · hardness 3.1 gpg (slightly hard) · 4 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 4 ppb | 4.9 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 11.2 ppb | 16.2 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 4.1 pCi/L | 4.1 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 2.6 ppb | 11.8 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Aluminum Can discolor water. | 0.02 ppm | 0.02 ppm | 0.2 guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.31 ppb | 0.43 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.05 ppm | 0.053 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2.3 ppb | 2.8 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 37 ppm | 37 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 9.8 ppb | 16.3 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.048 ppm | 0.17 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.9 ppb | 2.8 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 12.8 ppb | 20.1 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.018 ppm | 0.018 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0027 ppm | 0.003 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 2.9 ppb | 2.9 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.83 ppm | 1.1 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Simazine A weed killer that runs off fields and roadsides. | 0.07 ppb | 0.07 ppb | 4 ppb | 4 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 35.3 ppm | 35.4 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 12.5 ppm | 13 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 163 ppm | 163 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 16.4 ppb | 21.7 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 3.5 ppb | 3.9 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0051 ppm | 0.0051 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Hexadecanoic Acid.
Source: TCEQ Drinking Water Viewer, public water system ID TX1010919. 56 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010919.
Cy Champ Public Utility District serves about 6,726 people · hardness 5.4 gpg (moderately hard) · 9 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 3.7 ppb | 3.7 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.1 ppb | 5.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.5 ppb | 2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 9.8 ppb | 12.4 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 5 pCi/L | 5 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 4.5 pCi/L | 4.8 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 2.1 ppb | 5.2 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.5 pCi/L | 1.5 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Uranium Above health goal A naturally radioactive metal in Texas groundwater. | 3 ppb | 3 ppb | 30 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.16 ppb | 0.2 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.16 ppm | 0.27 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2.3 ppb | 2.9 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 43.5 ppm | 47 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 8 ppb | 19.3 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.072 ppm | 0.33 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.3 ppb | 1.3 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2.1 ppb | 3.8 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 13 ppb | 17.3 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Manganese Causes black staining and a bitter taste. | 0.03 ppm | 0.03 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 2.4 ppb | 2.5 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.3 ppb | 1.4 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.79 ppm | 1.1 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Simazine A weed killer that runs off fields and roadsides. | 0.08 ppb | 0.08 ppb | 4 ppb | 4 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 33.2 ppm | 35.2 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 24 ppm | 24 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 241 ppm | 262 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 18.8 ppb | 25.5 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 1.8 ppb | 2.4 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.006 ppm | 0.006 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Xylenes, Total, Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1011522. 61 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1011522.
Heatherloch Municipal Utility District serves about 6,612 people · hardness 4 gpg (moderately hard) · 4 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.3 ppb | 5.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1 ppb | 1 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 9.4 ppb | 13.2 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 4.4 ppb | 16.9 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.18 ppb | 0.25 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.059 ppm | 0.059 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 1.8 ppb | 2.9 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 43 ppm | 43 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 8.2 ppb | 17 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.083 ppm | 0.23 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Cyanide From industrial discharge and some natural sources. | 120 ppb | 120 ppb | 200 ppb | 200 ppb | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1 ppb | 1 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2.1 ppb | 4.1 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 11.2 ppb | 15.2 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Manganese Causes black staining and a bitter taste. | 0.002 ppm | 0.002 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 2.5 ppb | 2.8 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.4 ppb | 1.4 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.77 ppm | 1 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Simazine A weed killer that runs off fields and roadsides. | 0.07 ppb | 0.07 ppb | 4 ppb | 4 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 45.1 ppm | 45.1 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 22 ppm | 22 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 213 ppm | 213 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 15.3 ppb | 22.3 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 1.5 ppb | 1.8 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010548. 49 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010548.
Harris County Fresh Water Supply District 52 serves about 4,098 people · hardness 3.8 gpg (moderately hard) · 4 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.3 ppb | 3.8 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 7.2 ppb | 12.3 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 3.3 ppb | 12.1 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.5 pCi/L | 1.5 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.36 ppb | 0.49 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.058 ppm | 0.058 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2.4 ppb | 2.8 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 50 ppm | 50 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 8 ppb | 14 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.089 ppm | 0.74 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Cyanide From industrial discharge and some natural sources. | 160 ppb | 160 ppb | 200 ppb | 200 ppb | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.9 ppb | 2.8 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 8.8 ppb | 12.3 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Manganese Causes black staining and a bitter taste. | 0.0079 ppm | 0.0079 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 2.4 ppb | 2.4 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.2 ppb | 1.2 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.63 ppm | 0.68 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 42.8 ppm | 42.8 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 22 ppm | 22 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 200 ppm | 200 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 15 ppb | 17.9 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 2.3 ppb | 2.3 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010233. 40 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010233.
Harris County Water Control and Improvement District 116 serves about 3,627 people · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.5 ppb | 5.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 10 ppb | 10.8 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 2.1 ppb | 6.8 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2.1 ppb | 3.1 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 8.4 ppb | 14.4 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.021 ppm | 0.12 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1 ppb | 1 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.8 ppb | 3.7 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 11.5 ppb | 14.4 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 2.2 ppb | 2.2 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.29 ppm | 0.32 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 16.6 ppb | 20.2 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 1.4 ppb | 1.4 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010507. 28 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010507.
Harris County Municipal Utility District 191 serves about 3,465 people · hardness 5.6 gpg (moderately hard) · 4 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 2.9 ppb | 4.2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 9.2 ppb | 12 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 1.7 ppb | 3.3 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Uranium Above health goal A naturally radioactive metal in Texas groundwater. | 1.8 ppb | 1.8 ppb | 30 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.11 ppm | 0.11 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2 ppb | 2.1 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 28 ppm | 28 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 6 ppb | 11.7 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.065 ppm | 0.24 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.4 ppb | 2.7 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 11.1 ppb | 15.9 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Manganese Causes black staining and a bitter taste. | 0.0081 ppm | 0.0081 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 2.4 ppb | 2.4 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.2 ppb | 1.2 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.48 ppm | 0.56 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 38.9 ppm | 38.9 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 139 ppm | 139 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 11 ppb | 17.2 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 1.5 ppb | 1.5 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1012362. 37 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1012362.
Kleinwood Municipal Utility District serves about 3,340 people · hardness 3.5 gpg (slightly hard) · 7 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 9.7 ppb | 13.3 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.9 ppb | 6.2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 2.2 ppb | 3.8 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 7.7 ppb | 22.6 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 4.1 pCi/L | 4.1 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 8.7 ppb | 57.9 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.5 pCi/L | 1.5 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.11 ppb | 0.11 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.12 ppm | 0.18 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2.2 ppb | 3.8 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 55.4 ppm | 76 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 8.2 ppb | 24.4 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.053 ppm | 1.5 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.5 ppb | 1.9 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2.3 ppb | 6.9 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.68 ppm | 0.68 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 8.9 ppb | 26.4 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.24 ppm | 0.92 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.04 ppm | 0.1 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 4 ppb | 4.8 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.6 ppb | 1.6 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.37 ppm | 0.71 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Selenium A natural mineral that is harmful at high levels. | 4.1 ppb | 4.1 ppb | 50 ppb | 50 ppb | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 102 ppm | 162 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 10.3 ppm | 23.7 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 304 ppm | 449 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 13.9 ppb | 28.6 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 1.9 ppb | 3.8 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.076 ppm | 0.14 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010440. 221 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010440.
Bammel Utility District serves about 2,550 people · hardness 3.8 gpg (moderately hard) · 2 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 2.7 ppb | 3.2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 9.3 ppb | 11.8 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.36 ppb | 0.58 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.06 ppm | 0.06 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 1.9 ppb | 2.4 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 39 ppm | 39 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 6.4 ppb | 11 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.075 ppm | 0.11 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.6 ppb | 2.2 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 10.9 ppb | 13.6 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Manganese Causes black staining and a bitter taste. | 0.006 ppm | 0.006 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 3.1 ppb | 3.1 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.1 ppb | 1.1 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.67 ppm | 1 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 43.7 ppm | 43.7 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 15 ppm | 15 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 173 ppm | 173 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 9.7 ppb | 13.7 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 1.8 ppb | 1.8 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010365. 28 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010365.
Harris County MUD 551 serves about 1,269 people · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.5 ppb | 5.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 8.9 ppb | 17.9 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 0.65 ppb | 0.65 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2.1 ppb | 2.7 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 8.9 ppb | 18.4 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.018 ppm | 0.046 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.2 ppb | 1.4 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2.3 ppb | 3.5 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 10.8 ppb | 20.8 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 2.8 ppb | 2.8 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 14.3 ppb | 21.5 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 1.9 ppb | 2.9 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1013688. 22 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1013688.
Harris County Municipal Utility District 48 serves about 486 people · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.7 ppb | 1.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 3.6 ppb | 3.6 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 14.6 ppb | 63.3 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 1.3 ppb | 1.3 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 33.4 ppm | 34.2 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 2.6 ppb | 2.6 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.12 ppm | 0.54 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.5 ppb | 1.5 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 3.6 ppb | 3.6 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.13 ppm | 0.16 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.61 ppm | 0.8 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 31.6 ppm | 32.6 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 6.2 ppm | 6.3 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 200 ppm | 210 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 5.8 ppb | 5.8 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Hardness, Calcium Magnesium.
Source: TCEQ Drinking Water Viewer, public water system ID TX1010896. 17 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010896.
How We Treat Houston Water
This is what each of our systems does about the contaminants found in 77069.
| Found in 77069 | Water softener | AquaCarb PRO / ELITE | PureGuard RO / PureGuard ULTRA |
|---|---|---|---|
| Hardness (3.1–9.9 grains per gallon) | ✓ | – | ✓ |
| Arsenic | – | – | ✓ |
| Bromodichloromethane | – | ✓ | ✓ |
| Bromoform | – | ✓ | ✓ |
| Dichloroacetic acid | – | ✓ | ✓ |
| Gross alpha radioactivity | – | – | ✓ |
| Gross beta radioactivity | – | – | ✓ |
| Lead (home tap samples) | – | – | ✓ |
| Radium (combined 226 + 228) | ✓ | – | ✓ |
| Uranium | – | – | ✓ |
| Haloacetic acids (HAA5) | – | ✓ | ✓ |
| Iron | ✓ | – | – |
| Manganese | ✓ | – | – |
| Sodium | – | – | ✓ |
| Total dissolved solids (TDS) | – | – | ✓ |
| Total trihalomethanes (TTHMs) | – | ✓ | ✓ |
That is why our SENTINEL packages pair a whole-home system with a PureGuard RO & PureGuard ULTRA drinking water system. The softener and AquaCarb handle the water that goes on you. Reverse osmosis handles the water that goes in you. Salt delivery and filter changes are covered by the UnitedCare Membership.
About This Report
Test results come from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, covering samples collected October 2023 through October 2026. Legal limits and health goals are from the U.S. Environmental Protection Agency's National Primary and Secondary Drinking Water Regulations. "Average found" is the average of samples where the contaminant was detected.
Utility reports show the water the utility delivers. What comes out of your tap also depends on your home's plumbing. Lead and copper results come from samples taken at customers' taps. The best way to know what is in your water is to test it at your sink. We do that for free.
Every utility listed here is required to meet federal standards, and finding a contaminant above a health goal does not mean a utility is out of compliance.