Serving Houston and the surrounding areas Call 281-240-0261
United Water Softeners

Water Reports › Montgomery

ZIP 77316 Tap Water Quality Report

What the State of Texas found in the water utilities serving 77316 in Montgomery, TX, and how to treat it.

Get a Free Water Test Call 281-240-0261

One of our most commonly bought Sentinel ELITE Packages by United Water Softeners – ELITE CONNECT™ water softener and AQUACARB ELITE™ conditioner with PUREGUARD™ PGRO-450 reverse osmosis drinking water system.
9contaminants found above EPA health goals in at least one utility
2.4–15.7grains per gallon hardness (range across utilities in this ZIP): slightly hard to very hard
12water utilities with state test results in this ZIP

Found Above EPA Health Goals

An EPA health goal is the level at which no health risk is expected. Legal limits are often higher, because they also weigh the cost of treatment. These contaminants were found above the health goal in at least one utility serving 77316.

Lead (home tap samples)Found in 10 of 12 utilitiesHealth goal: zeroHighest utility average: 3.2 ppbRemoved by: PureGuard RO & PureGuard ULTRA
BromoformFound in 10 of 12 utilitiesHealth goal: zeroHighest utility average: 29.5 ppbRemoved by: AquaCarb PRO & AquaCarb ELITE, PureGuard RO & PureGuard ULTRA
BromodichloromethaneFound in 10 of 12 utilitiesHealth goal: zeroHighest utility average: 9.5 ppbRemoved by: AquaCarb PRO & AquaCarb ELITE, PureGuard RO & PureGuard ULTRA
Gross alpha radioactivityFound in 9 of 12 utilitiesHealth goal: zero · Legal limit: 15 pCi/LHighest utility average: 19 pCi/LRemoved by: PureGuard RO & PureGuard ULTRA
Gross beta radioactivityFound in 8 of 12 utilitiesHealth goal: zeroHighest utility average: 8.6 pCi/LRemoved by: PureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228)Found in 7 of 12 utilitiesHealth goal: zero · Legal limit: 5 pCi/LHighest utility average: 3.5 pCi/LRemoved by: Water softener, PureGuard RO & PureGuard ULTRA
Dichloroacetic acidFound in 6 of 12 utilitiesHealth goal: zeroHighest utility average: 8.4 ppbRemoved by: AquaCarb PRO & AquaCarb ELITE, PureGuard RO & PureGuard ULTRA
ArsenicFound in 4 of 12 utilitiesHealth goal: zero · Legal limit: 10 ppbHighest utility average: 7.3 ppbRemoved by: PureGuard RO & PureGuard ULTRA
UraniumFound in 3 of 12 utilitiesHealth goal: zero · Legal limit: 30 ppbHighest utility average: 4.1 ppbRemoved by: PureGuard RO & PureGuard ULTRA

Source: Test results from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, samples collected October 2023 through October 2026. Health goals and legal limits from the U.S. EPA National Primary Drinking Water Regulations. Each utility below lists its state water system ID so you can look up its records.

Results by Water Utility

Your water utility is the name on your water bill. Open it to see everything the state found in its water from October 2023 through October 2026.

City of Conroe serves about 89,956 people · hardness 4.4 gpg (moderately hard) · 6 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
5.3 ppb13.5 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
2.6 ppb8.9 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dichloroacetic acid Above health goal
A haloacetic acid disinfection byproduct.
5.4 ppb10.4 ppbpart of HAA5ZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
5.1 pCi/L7.6 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
7 pCi/L10.7 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.5 pCi/L1.5 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Aluminum
Can discolor water.
0.037 ppm0.053 ppm0.2 guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.12 ppm0.2 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Bromochloroacetic acid
A haloacetic acid disinfection byproduct.
3 ppb5.3 ppbNoneNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
33.2 ppm46 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
7.7 ppb16 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.14 ppm0.68 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
1.7 ppb2.7 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
4.4 ppb12.9 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.17 ppm0.21 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
11.9 ppb24 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.15 ppm0.29 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.0082 ppm0.013 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.26 ppm0.42 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Nitrate + nitrite
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.06 ppm0.07 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
50.8 ppm110 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
18.7 ppm25 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
283 ppm382 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
23.2 ppb44.4 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Trichloroacetic acid
A haloacetic acid disinfection byproduct.
4.7 ppb8.9 ppbpart of HAA520 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.0062 ppm0.0066 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Methyl Isobutyl Ketone, Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700001. 1148 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700001.

Montgomery Trace Water System serves about 20,016 people · hardness 8.4 gpg (hard) · 10 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Arsenic Above health goal
Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems.
7.3 ppb7.7 ppb10 ppbZeroPureGuard RO & PureGuard ULTRA
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.5 ppb3.9 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
1.9 ppb5.6 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dichloroacetic acid Above health goal
A haloacetic acid disinfection byproduct.
1 ppb1 ppbpart of HAA5ZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
6.1 pCi/L7 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
7.7 pCi/L10.4 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
3.2 ppb11 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Radium-226 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.4 pCi/L1.4 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-228 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.4 pCi/L1.4 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Uranium Above health goal
A naturally radioactive metal in Texas groundwater.
1.5 ppb1.5 ppb30 ppbZeroPureGuard RO & PureGuard ULTRA
Aluminum
Can discolor water.
0.046 ppm0.075 ppm0.2 guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.16 ppm0.27 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
36.9 ppm67.1 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
5.2 ppb15 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.1 ppm0.93 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
2.1 ppb14 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.18 ppm0.24 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
1 ppb1 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.18 ppm0.6 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.018 ppm0.069 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1.6 ppb2.2 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.16 ppm0.25 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
62.7 ppm140 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
21.9 ppm261 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
345 ppm500 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
2.8 ppb8.2 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.094 ppm0.25 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Hydroxide As Calcium Carbonate, Alkalinity, Carbonate, Methyl Isobutyl Ketone, 1,2,4-Trimethylbenzene, Xylenes, Total, Ethylbenzene, Gross Alpha, Incl. Radon & U, Alpha-Methyl-Styrene, Dimer, Texas Lead.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700638. 668 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700638.

Dobbin Plantersville Water Supply Corporation 1 serves about 4,248 people · hardness 8.9 gpg (hard) · 10 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Arsenic Above health goal
Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems.
4.6 ppb4.9 ppb10 ppbZeroPureGuard RO & PureGuard ULTRA
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
2.8 ppb6.3 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
29.5 ppb86 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dichloroacetic acid Above health goal
A haloacetic acid disinfection byproduct.
1.3 ppb1.3 ppbpart of HAA5ZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
6.2 pCi/L8.8 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
5.5 pCi/L6.2 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
2.2 ppb2.2 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
3.2 pCi/L3.6 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-226 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
2.1 pCi/L2.4 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-228 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.1 pCi/L1.2 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.17 ppm0.23 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Bromochloroacetic acid
A haloacetic acid disinfection byproduct.
2 ppb3.1 ppbNoneNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
105 ppm197 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.2 ppb1.2 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.039 ppm0.24 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
9 ppb12.9 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
9.1 ppb32.7 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.71 ppm1.8 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
8.7 ppb12.9 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.17 ppm0.78 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.046 ppm0.52 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1.7 ppb1.7 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.59 ppm0.7 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
119 ppm234 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
17.5 ppm33.2 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
538 ppm752 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
39.8 ppb116 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.059 ppm0.059 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Dibromomethane, Monobromoacetic Acid, Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700178. 210 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700178.

Stanley Lake Municipal Utility District serves about 3,783 people · hardness 6.6 gpg (moderately hard) · 9 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Arsenic Above health goal
Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems.
3.2 ppb3.2 ppb10 ppbZeroPureGuard RO & PureGuard ULTRA
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
2.1 ppb5.5 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
21.7 ppb77 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
8.4 pCi/L8.4 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
6.6 pCi/L9.2 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
1.3 ppb1.7 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
3 pCi/L3 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-226 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.9 pCi/L1.9 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-228 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.1 pCi/L1.1 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.098 ppm0.15 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
196 ppm400 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.2 ppb1.2 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.095 ppm0.58 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
2.6 ppb4 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
6.9 ppb24 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
2.2 ppm2.4 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
2.6 ppb4 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.29 ppm0.58 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.021 ppm0.043 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
2.5 ppb3.2 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Selenium
A natural mineral that is harmful at high levels.
6.7 ppb6.7 ppb50 ppb50 ppbPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
189 ppm358 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
25.3 ppm28 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
669 ppm1,030 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
13.2 ppb15.8 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.017 ppm0.028 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Alkalinity, Carbonate, Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700097. 76 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700097.

Lake Conroe Village serves about 2,550 people · hardness 9.1 gpg (hard) · 8 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.3 ppb1.4 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
1 ppb1 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
8 pCi/L8 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
8.2 pCi/L8.2 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
1.2 ppb1.2 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
2.5 pCi/L2.5 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-226 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.4 pCi/L1.4 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-228 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.1 pCi/L1.1 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.15 ppm0.15 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
48 ppm48 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.011 ppm0.024 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
1.5 ppb1.8 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.16 ppm0.16 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.3 ppm0.3 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.025 ppm0.025 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1.6 ppb1.6 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
59.2 ppm59.2 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
25 ppm25 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
403 ppm403 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
1.8 ppb2.9 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.041 ppm0.041 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700543. 26 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700543.

Lake Bonanza Water Supply Corporation serves about 2,142 people · hardness 8.2 gpg (hard) · 9 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.7 ppb2.5 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
2.4 ppb3.3 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dichloroacetic acid Above health goal
A haloacetic acid disinfection byproduct.
2.8 ppb2.8 ppbpart of HAA5ZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
11 pCi/L11 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
8.6 pCi/L8.6 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
1.6 ppb2.7 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
3.4 pCi/L3.4 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-226 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
2.4 pCi/L2.4 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-228 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1 pCi/L1 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.17 ppm0.17 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Bromochloroacetic acid
A haloacetic acid disinfection byproduct.
3 ppb3 ppbNoneNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
31 ppm31 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.2 ppb1.2 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.085 ppm0.39 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
3.7 ppb3.7 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
1.8 ppb3.8 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.22 ppm0.22 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
6.5 ppb6.5 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.28 ppm0.28 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.02 ppm0.02 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1 ppb1 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
73.1 ppm73.1 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
20 ppm20 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
391 ppm391 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
4.6 ppb10.8 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.0071 ppm0.0071 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700578. 30 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700578.

City of Montgomery serves about 1,650 people · hardness 2.8 gpg (slightly hard) · 4 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
9.5 ppb16.9 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
14.6 ppb41 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dichloroacetic acid Above health goal
A haloacetic acid disinfection byproduct.
2.1 ppb3.9 ppbpart of HAA5ZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
0.71 ppb0.81 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.043 ppm0.043 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Bromochloroacetic acid
A haloacetic acid disinfection byproduct.
3.2 ppb7 ppbNoneNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
137 ppm137 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
3.9 ppb6.1 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.065 ppm0.49 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
5.9 ppb11 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
19 ppb37.9 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
1.4 ppm1.4 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
8.2 ppb17.5 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.07 ppm0.07 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.011 ppm0.011 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.05 ppm0.05 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
157 ppm157 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
8 ppm8 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
503 ppm503 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
46.8 ppb84.8 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Trichloroacetic acid
A haloacetic acid disinfection byproduct.
1.6 ppb2.6 ppbpart of HAA520 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.01 ppm0.01 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Source: TCEQ Drinking Water Viewer, public water system ID TX1700022. 60 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700022.

Lake Conroe Forest Subdivision serves about 1,266 people · hardness 9.1 gpg (hard) · 4 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.1 ppb1.4 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
1.1 ppb1.1 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dichloroacetic acid Above health goal
A haloacetic acid disinfection byproduct.
8.4 ppb18.7 ppbpart of HAA5ZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
1.1 ppb1.3 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.16 ppm0.16 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Bromochloroacetic acid
A haloacetic acid disinfection byproduct.
8 ppb13.7 ppbNoneNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
36 ppm36 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.08 ppm0.19 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
5.8 ppb10 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
1.4 ppb1.9 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.15 ppm0.16 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
15.4 ppb38.3 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.11 ppm0.12 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.013 ppm0.014 ppm0.05 taste/stain guideline (ppm)None setWater softener
Monochloroacetic acid
A haloacetic acid disinfection byproduct.
5.2 ppb5.2 ppbpart of HAA570 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Nickel
A natural metal. No federal limit.
1.4 ppb1.4 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
63.8 ppm64.5 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
24 ppm24 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
368 ppm368 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
2.8 ppb3.3 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Trichloroacetic acid
A haloacetic acid disinfection byproduct.
4.4 ppb4.4 ppbpart of HAA520 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.02 ppm0.021 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Di(2-Ethylhexyl) Phthalate, Xylenes, Total.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700134. 40 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700134.

Keenan Water Supply Corporation serves about 1,239 people · hardness 9.9 gpg (hard) · 5 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.7 ppb3.4 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
1.4 ppb1.4 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
4.5 pCi/L5.4 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
6.3 pCi/L7.6 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
0.54 ppb0.54 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.19 ppm0.2 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
27.5 ppm28 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.7 ppb3.2 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.028 ppm0.12 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
1.9 ppb3.3 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.14 ppm0.15 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.44 ppm0.6 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.017 ppm0.02 ppm0.05 taste/stain guideline (ppm)None setWater softener
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
50 ppm54 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
18.5 ppm19 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
354 ppm360 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
3.9 ppb4.6 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.11 ppm0.11 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Xylenes, Total, Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700005. 42 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700005.

Sendera Ranch serves about 1,110 people · hardness 2.4 gpg (slightly hard) · 1 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
0.8 ppb1.2 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.099 ppm0.099 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
35.1 ppm36 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.1 ppb1.3 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.47 ppm0.92 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.031 ppm0.052 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.0046 ppm0.0046 ppm0.05 taste/stain guideline (ppm)None setWater softener
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
63.1 ppm64.7 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
9.7 ppm10 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
245 ppm250 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
1.1 ppb1.1 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Xylenes, Total.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700577. 48 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700577.

Lake Creek Forest serves about 822 people · hardness 4 gpg (moderately hard) · 4 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
2 pCi/L2 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
0.79 ppb1 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
3.5 pCi/L3.5 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Uranium Above health goal
A naturally radioactive metal in Texas groundwater.
2.2 ppb2.2 ppb30 ppbZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.14 ppm0.14 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
36 ppm36 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.065 ppm0.52 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.15 ppm0.15 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.048 ppm0.048 ppm0.3 taste/stain guideline (ppm)None setWater softener
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.08 ppm0.08 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
35.9 ppm35.9 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
7 ppm7 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
227 ppm227 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.77 ppm0.77 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Xylenes, Total, Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700529. 26 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700529.

Shady Oaks Estates serves about 648 people · hardness 15.7 gpg (very hard) · 8 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Arsenic Above health goal
Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems.
2.9 ppb2.9 ppb10 ppbZeroPureGuard RO & PureGuard ULTRA
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
5.3 ppb11 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
7.3 ppb11 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
19 pCi/L19 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
6 pCi/L6 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
2.9 pCi/L2.9 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-226 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
2.9 pCi/L2.9 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Uranium Above health goal
A naturally radioactive metal in Texas groundwater.
4.1 ppb4.1 ppb30 ppbZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.22 ppm0.23 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
95.5 ppm97 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
9.4 ppb11 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.13 ppm0.61 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
6.8 ppb16 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.23 ppm0.23 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.6 ppm0.79 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.03 ppm0.053 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
2.4 ppb2.8 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
60.7 ppm62.8 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
15.5 ppm16 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Toluene
An industrial solvent.
0.5 ppb0.5 ppb1,000 ppb1,000 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
464 ppm469 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.07 ppm0.087 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Acetone, Tetrahydrofuran, Xylenes, Total, Ethylbenzene, Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700632. 43 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700632.

How We Treat Montgomery Water

This is what each of our systems does about the contaminants found in 77316.

Found in 77316Water softenerAquaCarb PRO / ELITEPureGuard RO / PureGuard ULTRA
Hardness (2.4–15.7 grains per gallon)✓–✓
Arsenic––✓
Bromodichloromethane–✓✓
Bromoform–✓✓
Dichloroacetic acid–✓✓
Gross alpha radioactivity––✓
Gross beta radioactivity––✓
Lead (home tap samples)––✓
Radium (combined 226 + 228)✓–✓
Uranium––✓
Haloacetic acids (HAA5)–✓✓
Iron✓––
Manganese✓––
Sodium––✓
Total dissolved solids (TDS)––✓
Total trihalomethanes (TTHMs)–✓✓

That is why our SENTINEL packages pair a whole-home system with a PureGuard RO & PureGuard ULTRA drinking water system. The softener and AquaCarb handle the water that goes on you. Reverse osmosis handles the water that goes in you. Salt delivery and filter changes are covered by the UnitedCare Membership.

About This Report

Test results come from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, covering samples collected October 2023 through October 2026. Legal limits and health goals are from the U.S. Environmental Protection Agency's National Primary and Secondary Drinking Water Regulations. "Average found" is the average of samples where the contaminant was detected.

Utility reports show the water the utility delivers. What comes out of your tap also depends on your home's plumbing. Lead and copper results come from samples taken at customers' taps. The best way to know what is in your water is to test it at your sink. We do that for free.

Every utility listed here is required to meet federal standards, and finding a contaminant above a health goal does not mean a utility is out of compliance.

Want to know what is in YOUR water? Get a free in-home water test.

Free Water Test 281-240-0261