Serving Houston and the surrounding areas Call 281-240-0261
United Water Softeners

Water Reports › Willis

ZIP 77318 Tap Water Quality Report

What the State of Texas found in the water utilities serving 77318 in Willis, TX, and how to treat it.

Get a Free Water Test Call 281-240-0261

One of our most commonly bought Sentinel ELITE Packages by United Water Softeners – ELITE CONNECT™ water softener and AQUACARB ELITE™ conditioner with PUREGUARD™ PGRO-450 reverse osmosis drinking water system.
9contaminants found above EPA health goals in at least one utility
0.63–17.3grains per gallon hardness (range across utilities in this ZIP): soft to very hard
12water utilities with state test results in this ZIP

Found Above EPA Health Goals

An EPA health goal is the level at which no health risk is expected. Legal limits are often higher, because they also weigh the cost of treatment. These contaminants were found above the health goal in at least one utility serving 77318.

BromodichloromethaneFound in 11 of 12 utilitiesHealth goal: zeroHighest utility average: 5.3 ppbRemoved by: AquaCarb PRO & AquaCarb ELITE, PureGuard RO & PureGuard ULTRA
BromoformFound in 9 of 12 utilitiesHealth goal: zeroHighest utility average: 13.5 ppbRemoved by: AquaCarb PRO & AquaCarb ELITE, PureGuard RO & PureGuard ULTRA
Gross beta radioactivityFound in 9 of 12 utilitiesHealth goal: zeroHighest utility average: 8.5 pCi/LRemoved by: PureGuard RO & PureGuard ULTRA
Lead (home tap samples)Found in 6 of 12 utilitiesHealth goal: zeroHighest utility average: 1.9 ppbRemoved by: PureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228)Found in 5 of 12 utilitiesHealth goal: zero · Legal limit: 5 pCi/LHighest utility average: 3.3 pCi/LRemoved by: Water softener, PureGuard RO & PureGuard ULTRA
Gross alpha radioactivityFound in 3 of 12 utilitiesHealth goal: zero · Legal limit: 15 pCi/LHighest utility average: 8.6 pCi/LRemoved by: PureGuard RO & PureGuard ULTRA
ArsenicFound in 2 of 12 utilitiesHealth goal: zero · Legal limit: 10 ppbHighest utility average: 3.8 ppbRemoved by: PureGuard RO & PureGuard ULTRA
Dichloroacetic acidFound in 2 of 12 utilitiesHealth goal: zeroHighest utility average: 5.4 ppbRemoved by: AquaCarb PRO & AquaCarb ELITE, PureGuard RO & PureGuard ULTRA
UraniumFound in 1 of 12 utilitiesHealth goal: zero · Legal limit: 30 ppbHighest utility average: 1.8 ppbRemoved by: PureGuard RO & PureGuard ULTRA

Source: Test results from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, samples collected October 2023 through October 2026. Health goals and legal limits from the U.S. EPA National Primary Drinking Water Regulations. Each utility below lists its state water system ID so you can look up its records.

Results by Water Utility

Your water utility is the name on your water bill. Open it to see everything the state found in its water from October 2023 through October 2026.

City of Conroe serves about 113,912 people · hardness 4.4 gpg (moderately hard) · 6 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
5.3 ppb13.5 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
2.6 ppb8.9 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dichloroacetic acid Above health goal
A haloacetic acid disinfection byproduct.
5.4 ppb10.4 ppbpart of HAA5ZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
5.1 pCi/L7.6 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
7 pCi/L10.7 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.5 pCi/L1.5 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Aluminum
Can discolor water.
0.037 ppm0.053 ppm0.2 guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.12 ppm0.2 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Bromochloroacetic acid
A haloacetic acid disinfection byproduct.
3 ppb5.3 ppbNoneNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
33.2 ppm46 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
7.7 ppb16 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.14 ppm0.68 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
1.7 ppb2.7 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
4.4 ppb12.9 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.17 ppm0.21 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
11.9 ppb24 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.15 ppm0.29 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.0082 ppm0.013 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.26 ppm0.42 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Nitrate + nitrite
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.06 ppm0.07 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
50.8 ppm110 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
18.7 ppm25 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
283 ppm382 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
23.2 ppb44.4 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Trichloroacetic acid
A haloacetic acid disinfection byproduct.
4.7 ppb8.9 ppbpart of HAA520 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.0062 ppm0.0066 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Methyl Isobutyl Ketone, Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700001. 1148 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700001.

City of Willis serves about 14,133 people · hardness 6.3 gpg (moderately hard) · 4 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.5 ppb2.3 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
8.8 ppb31 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
6.5 pCi/L7.3 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
1.3 ppb2.5 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.15 ppm0.24 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
58 ppm117 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.021 ppm0.065 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
1.7 ppb1.7 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
4.2 ppb11 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
1.4 ppm1.4 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
1.7 ppb1.7 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.19 ppm0.33 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.014 ppm0.022 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1.2 ppb1.2 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.077 ppm0.09 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
109 ppm226 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
37.7 ppm84 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
450 ppm710 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
11.4 ppb14.8 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.075 ppm0.17 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Chloromethane, Bromomethane, Xylenes, Total.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700003. 82 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700003.

Montgomery County UD 2 serves about 3,381 people · hardness 9.3 gpg (hard) · 2 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.6 ppb2.5 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
1.3 ppb1.3 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.14 ppm0.14 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
28 ppm28 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1 ppb1 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.035 ppm0.22 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
1.8 ppb3 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.34 ppm0.34 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.025 ppm0.025 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1.3 ppb1.3 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
48.1 ppm48.1 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
19 ppm19 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
327 ppm327 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
2.6 ppb3.5 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA

Source: TCEQ Drinking Water Viewer, public water system ID TX1700115. 47 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700115.

Point Aquarius MUD serves about 3,228 people · hardness 1 gpg (slightly hard) · 6 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Arsenic Above health goal
Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems.
2.2 ppb2.2 ppb10 ppbZeroPureGuard RO & PureGuard ULTRA
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.6 ppb2.1 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
3 ppb4.6 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
0.5 ppb0.5 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1 pCi/L1 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-226 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1 pCi/L1 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.053 ppm0.053 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
148 ppm148 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.16 ppm0.37 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
1.1 ppb1.1 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
2.5 ppb5 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
1.1 ppm1.1 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
1.1 ppb1.1 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.43 ppm0.43 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.04 ppm0.04 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.06 ppm0.06 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
236 ppm236 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
106 ppm106 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
769 ppm769 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
8.3 ppb11.7 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.025 ppm0.025 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Texas Lead.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700060. 26 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700060.

City of Panorama Village serves about 2,800 people · hardness 0.96 gpg (soft) · 2 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
2.1 ppb5.3 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
8.9 ppb30 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.051 ppm0.054 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Bromochloroacetic acid
A haloacetic acid disinfection byproduct.
1 ppb1 ppbNoneNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
149 ppm149 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.4 ppb1.4 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.066 ppm0.1 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
2 ppb2.5 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
6.2 ppb19 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
1.6 ppm1.7 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
2 ppb2.5 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.19 ppm0.19 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.025 ppm0.026 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.08 ppm0.09 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
289 ppm299 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
88 ppm99 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
814 ppm841 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
15.4 ppb17.2 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.0068 ppm0.0068 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Thallium, Total, Xylenes, Total.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700026. 37 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700026.

Walnut Cove WSC serves about 2,076 people · hardness 8.7 gpg (hard) · 5 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
4.6 pCi/L4.6 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
5.5 pCi/L5.5 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
1.8 ppb3.1 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.7 pCi/L1.7 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-226 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.7 pCi/L1.7 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.19 ppm0.19 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
18 ppm18 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.023 ppm0.044 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.12 ppm0.12 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.17 ppm0.17 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.021 ppm0.021 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1.9 ppb1.9 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
40.1 ppm40.1 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
12 ppm12 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
302 ppm302 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.075 ppm0.075 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Gross Alpha, Incl. Radon & U, Texas Lead.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700389. 26 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700389.

Lake Conroe Hills MUD serves about 2,058 people · hardness 9.1 gpg (hard) · 3 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.8 ppb2.5 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
8.2 pCi/L8.2 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
1.8 ppb2.7 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.12 ppm0.12 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
25 ppm25 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
2.1 ppb2.7 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.066 ppm0.27 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
1.6 ppb1.7 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.15 ppm0.15 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.2 ppm0.2 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.021 ppm0.021 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1.4 ppb1.4 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
52.8 ppm52.8 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
20 ppm20 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
338 ppm338 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
5.9 ppb6.8 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.0057 ppm0.0057 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Source: TCEQ Drinking Water Viewer, public water system ID TX1700140. 26 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700140.

Far Hills Utility District serves about 2,030 people · 4 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
2.8 ppb3.3 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
11 ppb16.4 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
5.4 pCi/L5.4 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
1.9 ppb5.5 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.0081 ppm0.0081 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
98 ppm98 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.1 ppb1.3 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.078 ppm0.19 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
2.8 ppb3.2 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
7.2 ppb8.8 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
1.2 ppm1.2 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
2.8 ppb3.2 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.033 ppm0.033 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.0073 ppm0.0073 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.07 ppm0.07 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
154 ppm154 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
39 ppm39 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
474 ppm474 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
23.5 ppb28.2 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.0098 ppm0.0098 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Source: TCEQ Drinking Water Viewer, public water system ID TX1700011. 26 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700011.

Corinthian Point MUD 2 serves about 1,086 people · hardness 0.63 gpg (soft) · 4 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
4.7 ppb10.6 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
13.5 ppb22.2 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dichloroacetic acid Above health goal
A haloacetic acid disinfection byproduct.
1.3 ppb1.3 ppbpart of HAA5ZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
8.5 pCi/L8.5 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.039 ppm0.039 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Bromochloroacetic acid
A haloacetic acid disinfection byproduct.
1.7 ppb2.4 ppbNoneNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
120 ppm120 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.8 ppb2.7 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.0054 ppm0.0054 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromoacetic acid
A haloacetic acid disinfection byproduct.
3 ppb3.1 ppbpart of HAA5None setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
10.5 ppb19 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
1.4 ppm1.4 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Haloacetic acids (HAA5)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
3.4 ppb4.3 ppb60 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.071 ppm0.071 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.027 ppm0.027 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nitrate
From fertilizer, septic systems and natural deposits. High levels are dangerous for infants.
0.11 ppm0.11 ppm10 ppm10 ppmPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
218 ppm218 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
114 ppm114 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
694 ppm694 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
40.6 ppb45.6 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA

Source: TCEQ Drinking Water Viewer, public water system ID TX1700152. 26 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700152.

Shadow Bay Subdivision serves about 828 people · hardness 9.3 gpg (hard) · 3 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.4 ppb2.1 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
7.5 pCi/L7.5 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Lead (home tap samples) Above health goal
No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility.
1.1 ppb1.1 ppb15 action level (ppb)ZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.12 ppm0.12 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
17 ppm17 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.3 ppb1.8 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.025 ppm0.078 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
1.2 ppb1.3 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.34 ppm0.34 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.018 ppm0.018 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1.1 ppb1.1 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
40.6 ppm40.6 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
19 ppm19 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
314 ppm314 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
3.8 ppb4.2 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.032 ppm0.032 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Xylenes, Total, Benzene.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700393. 28 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700393.

Hulon Lakes Subdivision serves about 771 people · hardness 17.3 gpg (very hard) · 9 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Arsenic Above health goal
Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems.
3.8 ppb4.6 ppb10 ppbZeroPureGuard RO & PureGuard ULTRA
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1 ppb1 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
2 ppb2 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross alpha radioactivity Above health goal
Natural radioactivity from uranium and radium in groundwater.
8.6 pCi/L18 pCi/L15 pCi/LZeroPureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
7.5 pCi/L11.5 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
3.3 pCi/L3.9 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-226 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
2.6 pCi/L2.8 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Radium-228 (part of combined radium) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.2 pCi/L1.4 pCi/L5 combined (pCi/L)ZeroWater softener
PureGuard RO & PureGuard ULTRA
Uranium Above health goal
A naturally radioactive metal in Texas groundwater.
1.8 ppb3.6 ppb30 ppbZeroPureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.31 ppm0.35 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
70.3 ppm84 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.022 ppm0.07 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
1.7 ppb1.7 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.32 ppm0.32 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.24 ppm0.31 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.047 ppm0.065 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
2.8 ppb4.2 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Selenium
A natural mineral that is harmful at high levels.
6.5 ppb7.2 ppb50 ppb50 ppbPureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
33.9 ppm40.9 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
9.7 ppm13 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
453 ppm471 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.057 ppm0.078 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Also detected (no federal limit or health goal): Xylenes, Total, Gross Alpha, Incl. Radon & U.

Source: TCEQ Drinking Water Viewer, public water system ID TX1700014. 66 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700014.

Montgomery County FWSD 6 serves about 426 people · hardness 9.9 gpg (hard) · 4 above health goals
ContaminantAverage foundHighest foundLegal limitEPA health goalRemoved by
Bromodichloromethane Above health goal
A trihalomethane disinfection byproduct.
1.8 ppb2.3 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Bromoform Above health goal
A trihalomethane disinfection byproduct.
1.1 ppb1.2 ppbpart of TTHMsZeroAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Gross beta radioactivity Above health goal
Radioactivity from natural and man-made sources.
6.2 pCi/L6.2 pCi/L50 screening level (pCi/L)ZeroPureGuard RO & PureGuard ULTRA
Radium (combined 226 + 228) Above health goal
Naturally radioactive. Long-term exposure is linked to cancer.
1.5 pCi/L1.5 pCi/L5 pCi/LZeroWater softener
PureGuard RO & PureGuard ULTRA
Barium
A natural metal. High levels can raise blood pressure.
0.14 ppm0.14 ppm2 ppm2 ppmWater softener
PureGuard RO & PureGuard ULTRA
Chloride
Gives water a salty taste.
20 ppm20 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Chloroform
A trihalomethane disinfection byproduct.
1.2 ppb1.2 ppbpart of TTHMs70 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Copper (home tap samples)
Usually comes from household copper plumbing.
0.034 ppm0.061 ppm1.3 action level (ppm)1.3 ppmPureGuard RO & PureGuard ULTRA
Dibromochloromethane
A trihalomethane disinfection byproduct.
2.2 ppb2.7 ppbpart of TTHMs60 ppbAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Fluoride
Natural or added by the utility. Very high levels can affect teeth and bones.
0.13 ppm0.13 ppm4 ppm4 ppmPureGuard RO & PureGuard ULTRA
Iron
Causes rust stains and a metallic taste.
0.17 ppm0.17 ppm0.3 taste/stain guideline (ppm)None setWater softener
Manganese
Causes black staining and a bitter taste.
0.027 ppm0.027 ppm0.05 taste/stain guideline (ppm)None setWater softener
Nickel
A natural metal. No federal limit.
1.3 ppb1.3 ppbNoneNone setWater softener
PureGuard RO & PureGuard ULTRA
Sodium
No federal limit. EPA advises 20 ppm or less for people on low-sodium diets.
41.6 ppm41.6 ppmNoneNone setPureGuard RO & PureGuard ULTRA
Sulfate
Can give water a bitter taste.
22 ppm22 ppm250 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total dissolved solids (TDS)
Everything dissolved in the water. High TDS affects taste.
320 ppm320 ppm500 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA
Total trihalomethanes (TTHMs)
Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer.
7.3 ppb7.3 ppb80 ppbNone setAquaCarb PRO & AquaCarb ELITE
PureGuard RO & PureGuard ULTRA
Zinc
Can give water a metallic taste.
0.035 ppm0.035 ppm5 taste guideline (ppm)None setPureGuard RO & PureGuard ULTRA

Source: TCEQ Drinking Water Viewer, public water system ID TX1700142. 17 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700142.

How We Treat Willis Water

This is what each of our systems does about the contaminants found in 77318.

Found in 77318Water softenerAquaCarb PRO / ELITEPureGuard RO / PureGuard ULTRA
Hardness (0.63–17.3 grains per gallon)✓–✓
Arsenic––✓
Bromodichloromethane–✓✓
Bromoform–✓✓
Dichloroacetic acid–✓✓
Gross alpha radioactivity––✓
Gross beta radioactivity––✓
Lead (home tap samples)––✓
Radium (combined 226 + 228)✓–✓
Uranium––✓
Haloacetic acids (HAA5)–✓✓
Iron✓––
Manganese✓––
Sodium––✓
Total dissolved solids (TDS)––✓
Total trihalomethanes (TTHMs)–✓✓

That is why our SENTINEL packages pair a whole-home system with a PureGuard RO & PureGuard ULTRA drinking water system. The softener and AquaCarb handle the water that goes on you. Reverse osmosis handles the water that goes in you. Salt delivery and filter changes are covered by the UnitedCare Membership.

About This Report

Test results come from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, covering samples collected October 2023 through October 2026. Legal limits and health goals are from the U.S. Environmental Protection Agency's National Primary and Secondary Drinking Water Regulations. "Average found" is the average of samples where the contaminant was detected.

Utility reports show the water the utility delivers. What comes out of your tap also depends on your home's plumbing. Lead and copper results come from samples taken at customers' taps. The best way to know what is in your water is to test it at your sink. We do that for free.

Every utility listed here is required to meet federal standards, and finding a contaminant above a health goal does not mean a utility is out of compliance.

Want to know what is in YOUR water? Get a free in-home water test.

Free Water Test 281-240-0261