ZIP 77356 Tap Water Quality Report
What the State of Texas found in the water utilities serving 77356 in Montgomery, TX, and how to treat it.
Found Above EPA Health Goals
An EPA health goal is the level at which no health risk is expected. Legal limits are often higher, because they also weigh the cost of treatment. These contaminants were found above the health goal in at least one utility serving 77356.
Source: Test results from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, samples collected October 2023 through October 2026. Health goals and legal limits from the U.S. EPA National Primary Drinking Water Regulations. Each utility below lists its state water system ID so you can look up its records.
Results by Water Utility
Your water utility is the name on your water bill. Open it to see everything the state found in its water from October 2023 through October 2026.
City of Conroe serves about 89,956 people · hardness 4.4 gpg (moderately hard) · 6 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 5.3 ppb | 13.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 2.6 ppb | 8.9 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 5.4 ppb | 10.4 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 5.1 pCi/L | 7.6 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 7 pCi/L | 10.7 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.5 pCi/L | 1.5 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Aluminum Can discolor water. | 0.037 ppm | 0.053 ppm | 0.2 guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.12 ppm | 0.2 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 3 ppb | 5.3 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 33.2 ppm | 46 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 7.7 ppb | 16 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.14 ppm | 0.68 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.7 ppb | 2.7 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 4.4 ppb | 12.9 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.17 ppm | 0.21 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 11.9 ppb | 24 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.15 ppm | 0.29 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0082 ppm | 0.013 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.26 ppm | 0.42 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Nitrate + nitrite From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.06 ppm | 0.07 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 50.8 ppm | 110 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 18.7 ppm | 25 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 283 ppm | 382 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 23.2 ppb | 44.4 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 4.7 ppb | 8.9 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0062 ppm | 0.0066 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Methyl Isobutyl Ketone, Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700001. 1148 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700001.
Montgomery County Municipal Utility District 18 serves about 7,608 people · hardness 2.2 gpg (slightly hard) · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.7 ppb | 6.3 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 18.7 ppb | 39 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 0.87 ppb | 1.1 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.04 ppm | 0.069 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2.3 ppb | 2.7 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 79.5 ppm | 90 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.5 ppb | 2.1 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.035 ppm | 0.099 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 5.5 ppb | 9.4 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 11.5 ppb | 21 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.78 ppm | 0.95 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 5.5 ppb | 9.4 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.012 ppm | 0.013 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.01 ppm | 0.014 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.07 ppm | 0.07 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 135 ppm | 164 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 39.5 ppm | 51 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 459 ppm | 505 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 43 ppb | 51.6 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Xylenes, Total, Ethylbenzene.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700546. 48 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700546.
Montgomery County Municipal Utility District 9 serves about 5,949 people · hardness 8.9 gpg (hard) · 7 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.1 ppb | 5.4 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 7.6 ppb | 20 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 6.5 pCi/L | 6.5 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 9.1 pCi/L | 9.1 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 1 ppb | 1.3 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.6 pCi/L | 1.6 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-226 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.6 pCi/L | 1.6 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.068 ppm | 0.12 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 1.3 ppb | 1.5 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 65 ppm | 98 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.7 ppb | 2.1 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.033 ppm | 0.12 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 2.7 ppb | 3.3 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 5.8 ppb | 10.5 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 1 ppm | 1.8 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 2.7 ppb | 3.3 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.067 ppm | 0.11 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0095 ppm | 0.015 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.3 ppb | 1.3 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 117 ppm | 179 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 37.5 ppm | 52 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 447 ppm | 547 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 27.2 ppb | 32.6 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.011 ppm | 0.011 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Methyl Isobutyl Ketone, Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700220. 52 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700220.
Montgomery County Municipal Utility District 8 serves about 5,472 people · hardness 5 gpg (moderately hard) · 7 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 2 ppb | 3.3 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 22.4 ppb | 49 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 7.2 pCi/L | 7.2 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 6.6 pCi/L | 8.9 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 8.5 ppb | 30.6 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.6 pCi/L | 1.6 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-226 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.6 pCi/L | 1.6 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.076 ppm | 0.11 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 1 ppb | 1 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 135 ppm | 239 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.2 ppb | 1.5 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.099 ppm | 0.5 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 2 ppb | 2.5 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 4.7 ppb | 10.2 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 1.5 ppm | 1.5 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 2 ppb | 2.5 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.076 ppm | 0.085 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.012 ppm | 0.019 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 165 ppm | 270 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 34 ppm | 43 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 547 ppm | 741 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 18.5 ppb | 31.7 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0052 ppm | 0.0052 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700176. 53 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700176.
Montgomery County UD 4 serves about 4,932 people · hardness 9.2 gpg (hard) · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 2.2 ppb | 3.4 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 9.1 ppb | 14 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 19.8 ppb | 143 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.14 ppm | 0.14 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 1.1 ppb | 1.3 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 43.8 ppm | 102 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.1 ppm | 0.68 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.7 ppb | 2.1 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 5.8 ppb | 10.7 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 1.7 ppb | 2.1 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.17 ppm | 0.22 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.019 ppm | 0.026 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.3 ppb | 1.3 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 78.9 ppm | 178 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 21.8 ppm | 24 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 379 ppm | 564 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 18.9 ppb | 28.1 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Thallium, Total, Methyl Isobutyl Ketone.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700286. 48 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700286.
Dobbin Plantersville Water Supply Corporation 1 serves about 4,248 people · hardness 8.9 gpg (hard) · 10 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 4.6 ppb | 4.9 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 2.8 ppb | 6.3 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 29.5 ppb | 86 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 1.3 ppb | 1.3 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 6.2 pCi/L | 8.8 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 5.5 pCi/L | 6.2 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 2.2 ppb | 2.2 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 3.2 pCi/L | 3.6 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-226 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 2.1 pCi/L | 2.4 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-228 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.1 pCi/L | 1.2 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.17 ppm | 0.23 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2 ppb | 3.1 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 105 ppm | 197 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.2 ppb | 1.2 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.039 ppm | 0.24 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 9 ppb | 12.9 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 9.1 ppb | 32.7 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.71 ppm | 1.8 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 8.7 ppb | 12.9 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.17 ppm | 0.78 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.046 ppm | 0.52 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.7 ppb | 1.7 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.59 ppm | 0.7 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 119 ppm | 234 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 17.5 ppm | 33.2 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 538 ppm | 752 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 39.8 ppb | 116 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.059 ppm | 0.059 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Dibromomethane, Monobromoacetic Acid, Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700178. 210 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700178.
Montgomery County UD 3 serves about 3,966 people · hardness 4.4 gpg (moderately hard) · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 2 ppb | 2.3 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 4.3 ppb | 11 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 4.1 ppb | 17.5 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.079 ppm | 0.079 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 117 ppm | 117 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.3 ppb | 1.4 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.089 ppm | 0.71 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 3.6 ppb | 6.9 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 1.1 ppm | 1.1 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.12 ppm | 0.12 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.02 ppm | 0.02 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.05 ppm | 0.05 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 186 ppm | 186 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 19 ppm | 19 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 570 ppm | 570 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 5.8 ppb | 6.2 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0055 ppm | 0.0055 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): 1,2,4-Trimethylbenzene.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700116. 37 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700116.
Stanley Lake Municipal Utility District serves about 3,783 people · hardness 6.6 gpg (moderately hard) · 9 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 3.2 ppb | 3.2 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 2.1 ppb | 5.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 21.7 ppb | 77 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 8.4 pCi/L | 8.4 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 6.6 pCi/L | 9.2 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 1.3 ppb | 1.7 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 3 pCi/L | 3 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-226 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.9 pCi/L | 1.9 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-228 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.1 pCi/L | 1.1 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.098 ppm | 0.15 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 196 ppm | 400 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.2 ppb | 1.2 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.095 ppm | 0.58 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 2.6 ppb | 4 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 6.9 ppb | 24 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 2.2 ppm | 2.4 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 2.6 ppb | 4 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.29 ppm | 0.58 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.021 ppm | 0.043 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 2.5 ppb | 3.2 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Selenium A natural mineral that is harmful at high levels. | 6.7 ppb | 6.7 ppb | 50 ppb | 50 ppb | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 189 ppm | 358 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 25.3 ppm | 28 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 669 ppm | 1,030 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 13.2 ppb | 15.8 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.017 ppm | 0.028 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Alkalinity, Carbonate, Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700097. 76 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700097.
Dobbin Plantersville Water Supply Corporation 2 serves about 2,766 people · hardness 10.4 gpg (hard) · 9 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 3.2 ppb | 3.8 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 3.1 ppb | 4.8 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.1 ppb | 1.1 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 12.4 pCi/L | 18.3 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 9 pCi/L | 12.5 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 0.96 ppb | 1.3 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 2.9 pCi/L | 3.2 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-226 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 2.2 pCi/L | 3.2 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-228 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.3 pCi/L | 1.3 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.16 ppm | 0.17 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 41.5 ppm | 50 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 6.6 ppb | 6.6 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.052 ppm | 0.32 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2.9 ppb | 4 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.24 ppm | 0.25 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.2 ppm | 0.52 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.024 ppm | 0.037 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 78.9 ppm | 112 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 20 ppm | 26 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 472 ppm | 520 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 4.3 ppb | 4.3 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0095 ppm | 0.0095 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Xylenes, Total, Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX0930049. 48 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX0930049.
Lake Conroe Village serves about 2,550 people · hardness 9.1 gpg (hard) · 8 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.3 ppb | 1.4 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1 ppb | 1 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 8 pCi/L | 8 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 8.2 pCi/L | 8.2 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 1.2 ppb | 1.2 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 2.5 pCi/L | 2.5 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-226 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.4 pCi/L | 1.4 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-228 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.1 pCi/L | 1.1 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.15 ppm | 0.15 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 48 ppm | 48 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.011 ppm | 0.024 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.5 ppb | 1.8 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.16 ppm | 0.16 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.3 ppm | 0.3 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.025 ppm | 0.025 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.6 ppb | 1.6 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 59.2 ppm | 59.2 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 25 ppm | 25 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 403 ppm | 403 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 1.8 ppb | 2.9 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.041 ppm | 0.041 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700543. 26 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700543.
Lake Bonanza Water Supply Corporation serves about 2,142 people · hardness 8.2 gpg (hard) · 9 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.7 ppb | 2.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 2.4 ppb | 3.3 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 2.8 ppb | 2.8 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 11 pCi/L | 11 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 8.6 pCi/L | 8.6 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 1.6 ppb | 2.7 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 3.4 pCi/L | 3.4 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-226 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 2.4 pCi/L | 2.4 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-228 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1 pCi/L | 1 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.17 ppm | 0.17 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 3 ppb | 3 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 31 ppm | 31 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.2 ppb | 1.2 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.085 ppm | 0.39 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 3.7 ppb | 3.7 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.8 ppb | 3.8 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.22 ppm | 0.22 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 6.5 ppb | 6.5 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.28 ppm | 0.28 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.02 ppm | 0.02 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1 ppb | 1 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 73.1 ppm | 73.1 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 20 ppm | 20 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 391 ppm | 391 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 4.6 ppb | 10.8 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0071 ppm | 0.0071 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700578. 30 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700578.
Grand Harbor Water System serves about 1,947 people · hardness 10.8 gpg (very hard) · 5 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 2.3 ppb | 2.3 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 6.3 ppb | 18 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 5 ppb | 16 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 7.4 ppb | 7.4 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 4.6 ppb | 23.4 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.15 ppm | 0.17 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 7.9 ppb | 7.9 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 51.7 ppm | 63.6 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 3.8 ppb | 8.3 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.095 ppm | 0.6 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 6 ppb | 6 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 7.3 ppb | 27 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.14 ppm | 0.14 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 15.4 ppb | 15.4 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.096 ppm | 0.2 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.032 ppm | 0.051 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 2 ppb | 2.5 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 53.9 ppm | 144 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 20 ppm | 25.5 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Toluene An industrial solvent. | 0.7 ppb | 0.7 ppb | 1,000 ppb | 1,000 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 359 ppm | 442 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 9.2 ppb | 15.5 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 2 ppb | 2 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.046 ppm | 0.046 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): 2,4-D, Acetone, Methyl Ethyl Ketone, Methyl Isobutyl Ketone, Xylenes, Total, Ethylbenzene.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700643. 150 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700643.
How We Treat Montgomery Water
This is what each of our systems does about the contaminants found in 77356.
| Found in 77356 | Water softener | AquaCarb PRO / ELITE | PureGuard RO / PureGuard ULTRA |
|---|---|---|---|
| Hardness (2.2–10.8 grains per gallon) | ✓ | – | ✓ |
| Arsenic | – | – | ✓ |
| Bromodichloromethane | – | ✓ | ✓ |
| Bromoform | – | ✓ | ✓ |
| Dichloroacetic acid | – | ✓ | ✓ |
| Gross alpha radioactivity | – | – | ✓ |
| Gross beta radioactivity | – | – | ✓ |
| Lead (home tap samples) | – | – | ✓ |
| Radium (combined 226 + 228) | ✓ | – | ✓ |
| Haloacetic acids (HAA5) | – | ✓ | ✓ |
| Iron | ✓ | – | – |
| Manganese | ✓ | – | – |
| Sodium | – | – | ✓ |
| Total dissolved solids (TDS) | – | – | ✓ |
| Total trihalomethanes (TTHMs) | – | ✓ | ✓ |
That is why our SENTINEL packages pair a whole-home system with a PureGuard RO & PureGuard ULTRA drinking water system. The softener and AquaCarb handle the water that goes on you. Reverse osmosis handles the water that goes in you. Salt delivery and filter changes are covered by the UnitedCare Membership.
About This Report
Test results come from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, covering samples collected October 2023 through October 2026. Legal limits and health goals are from the U.S. Environmental Protection Agency's National Primary and Secondary Drinking Water Regulations. "Average found" is the average of samples where the contaminant was detected.
Utility reports show the water the utility delivers. What comes out of your tap also depends on your home's plumbing. Lead and copper results come from samples taken at customers' taps. The best way to know what is in your water is to test it at your sink. We do that for free.
Every utility listed here is required to meet federal standards, and finding a contaminant above a health goal does not mean a utility is out of compliance.