ZIP 77373 Tap Water Quality Report
What the State of Texas found in the water utilities serving 77373 in Spring, TX, and how to treat it.

Found Above EPA Health Goals
An EPA health goal is the level at which no health risk is expected. Legal limits are often higher, because they also weigh the cost of treatment. These contaminants were found above the health goal in at least one utility serving 77373.
Source: Test results from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, samples collected October 2023 through October 2026. Health goals and legal limits from the U.S. EPA National Primary Drinking Water Regulations. Each utility below lists its state water system ID so you can look up its records.
Results by Water Utility
Your water utility is the name on your water bill. Open it to see everything the state found in its water from October 2023 through October 2026.
Timber Lane Utility District serves about 24,507 people · hardness 6.4 gpg (moderately hard) · 4 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 3.3 ppb | 4 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 2.5 ppb | 9.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 2.9 ppb | 10.2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 2 ppb | 17.7 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Aluminum Can discolor water. | 0.029 ppm | 0.029 ppm | 0.2 guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.16 ppm | 0.26 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 63.2 ppm | 650 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.6 ppb | 2 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.038 ppm | 0.19 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.3 ppb | 1.3 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 3.1 ppb | 19.2 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.82 ppm | 0.85 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 5 ppb | 5.5 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 33.6 ppm | 463 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 109 ppm | 474 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 4.4 ppb | 4.6 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.3 ppb | 1.3 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.29 ppm | 0.35 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 93.7 ppm | 447 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 31.5 ppm | 642 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 280 ppm | 651 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 4.4 ppb | 40.9 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0055 ppm | 0.0055 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Acetone.
Source: TCEQ Drinking Water Viewer, public water system ID TX1010278. 344 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010278.
Harris County MUD 82 serves about 18,990 people · hardness 3.7 gpg (moderately hard) · 6 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 2.9 ppb | 3.2 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.8 ppb | 4.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.6 ppb | 3.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 1.3 ppb | 1.3 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 2.1 ppb | 5.9 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.5 pCi/L | 1.5 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.15 ppm | 0.3 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 1 ppb | 1 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 42.3 ppm | 46 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.8 ppb | 2.3 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.047 ppm | 0.17 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.1 ppb | 1.1 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2.3 ppb | 6.1 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.83 ppm | 0.98 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 2 ppb | 4.5 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.046 ppm | 0.054 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0058 ppm | 0.0068 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 4.5 ppb | 4.5 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.2 ppb | 1.2 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.23 ppm | 0.23 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 108 ppm | 138 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 349 ppm | 384 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 4.5 ppb | 9 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010630. 108 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010630.
Southern Montgomery County MUD serves about 15,966 people · hardness 4.9 gpg (moderately hard) · 5 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 3.9 ppb | 3.9 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 7.5 ppb | 19.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 6.1 ppb | 18.9 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 4.4 ppb | 9.5 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 0.75 ppb | 1.1 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.13 ppm | 0.2 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2.6 ppb | 5.3 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 49 ppm | 58 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 9.9 ppb | 20.1 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.088 ppm | 0.2 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 2.3 ppb | 3.6 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 10 ppb | 26.9 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.68 ppm | 0.78 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 10.1 ppb | 19.8 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.098 ppm | 0.16 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0018 ppm | 0.0034 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.17 ppm | 0.2 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 70.9 ppm | 108 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 8.5 ppm | 10 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 281 ppm | 334 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 38.2 ppb | 72.3 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 3.4 ppb | 6.7 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0077 ppm | 0.0077 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Xylenes, Total, Ethylbenzene.
Source: TCEQ Drinking Water Viewer, public water system ID TX1700073. 92 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700073.
Harris County WCID 110 serves about 9,807 people · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 4.9 ppb | 4.9 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 12.1 ppb | 12.1 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 4.1 ppb | 21.8 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 3.3 ppb | 3.3 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 52.5 ppm | 62 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 14.4 ppb | 15 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.083 ppm | 0.46 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Cyanide From industrial discharge and some natural sources. | 70 ppb | 80 ppb | 200 ppb | 200 ppb | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1 ppb | 1 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.8 ppb | 1.8 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.73 ppm | 0.73 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 16.1 ppb | 16.1 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.24 ppm | 0.25 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 15 ppm | 16 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 302 ppm | 387 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 20.4 ppb | 20.4 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 3 ppb | 3 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010482. 36 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010482.
Hunters Glen MUD serves about 9,405 people · hardness 8.1 gpg (hard) · 5 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 5 ppb | 7.9 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.1 ppb | 1.1 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 1.3 ppb | 1.3 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 4.6 pCi/L | 4.6 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 2 ppb | 4.9 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.31 ppm | 0.34 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 37 ppm | 38 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 5.5 ppb | 8.4 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.034 ppm | 0.16 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2 ppb | 4.3 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 1.3 ppb | 1.3 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.02 ppm | 0.02 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0011 ppm | 0.0011 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.2 ppb | 1.3 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.25 ppm | 0.28 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 32.6 ppm | 33.3 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 259 ppm | 259 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 6.6 ppb | 21.7 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.013 ppm | 0.013 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): 2,4-D, Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1010615. 99 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010615.
Harris County MUD 43 serves about 6,873 people · hardness 3.7 gpg (moderately hard) · 1 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 3.2 ppb | 3.9 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.27 ppm | 0.27 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 42.6 ppm | 83.5 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.038 ppm | 0.17 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.11 ppm | 0.11 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.11 ppm | 0.44 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.026 ppm | 0.035 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.4 ppb | 1.4 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.26 ppm | 0.27 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 112 ppm | 160 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 4.9 ppm | 7.6 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 330 ppm | 438 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.01 ppm | 0.01 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010565. 87 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010565.
Benders Landing Water Plant 1 & 2 serves about 5,892 people · hardness 8.2 gpg (hard) · 1 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 3.3 ppb | 22 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.27 ppm | 0.28 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 38.3 ppm | 42 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.089 ppm | 0.24 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.11 ppm | 0.11 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.3 ppb | 1.5 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.09 ppm | 0.11 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 33.9 ppm | 35.9 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 6 ppm | 6 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 265 ppm | 269 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0063 ppm | 0.007 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1700678. 59 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700678.
Tattor Road MUD serves about 5,400 people · hardness 8.1 gpg (hard) · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 2.1 ppb | 2.1 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.4 ppb | 1.8 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 0.88 ppb | 1.1 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.29 ppm | 0.29 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 38 ppm | 38 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.011 ppm | 0.094 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.9 ppb | 2.2 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.1 ppb | 1.1 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.21 ppm | 0.21 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Selenium A natural mineral that is harmful at high levels. | 4 ppb | 4 ppb | 50 ppb | 50 ppb | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 36.6 ppm | 36.6 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 275 ppm | 275 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 3.3 ppb | 4 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010625. 36 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010625.
Montgomery County MUD 94 serves about 5,184 people · hardness 2.3 gpg (slightly hard) · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.6 ppb | 1.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.1 ppb | 1.2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 1.2 ppb | 1.6 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.13 ppm | 0.13 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 41 ppm | 41 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.051 ppm | 0.58 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.8 ppb | 2.3 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.81 ppm | 0.81 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.034 ppm | 0.034 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0071 ppm | 0.0071 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 130 ppm | 130 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 382 ppm | 382 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 3.1 ppb | 5.2 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1700716. 35 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1700716.
Harris County WCID 92 serves about 4,752 people · hardness 9.2 gpg (hard) · 2 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.8 ppb | 2.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.5 ppb | 1.6 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.28 ppm | 0.28 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1 ppb | 1 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.25 ppm | 0.28 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2.7 ppb | 3.3 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.1 ppb | 1.1 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.23 ppm | 0.23 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 32.4 ppm | 32.4 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 6.5 ppb | 8.4 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0078 ppm | 0.0078 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010124. 28 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010124.
Northgate Crossing MUD 1 serves about 3,906 people · hardness 1.8 gpg (slightly hard) · 2 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.9 ppb | 3.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.3 ppb | 1.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.12 ppm | 0.12 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 43 ppm | 43 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.2 ppb | 1.2 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.01 ppm | 0.024 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.9 ppb | 3.6 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.69 ppm | 0.69 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.047 ppm | 0.047 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0083 ppm | 0.0083 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.5 ppb | 1.5 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 132 ppm | 132 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 5 ppm | 5 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 370 ppm | 370 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 4.5 ppb | 9.8 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0051 ppm | 0.0051 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Methyl Isobutyl Ketone.
Source: TCEQ Drinking Water Viewer, public water system ID TX1013077. 29 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1013077.
Postwood MUD serves about 3,747 people · hardness 8 gpg (hard) · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.1 ppb | 1.1 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.2 ppb | 1.4 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 1.7 ppb | 4 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.29 ppm | 0.29 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 44 ppm | 44 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.089 ppm | 0.27 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.6 ppb | 1.6 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.049 ppm | 0.049 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.4 ppb | 1.4 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.23 ppm | 0.23 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 34.9 ppm | 34.9 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 285 ppm | 285 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 2.7 ppb | 2.9 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0055 ppm | 0.0055 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1010631. 36 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010631.
How We Treat Spring Water
This is what each of our systems does about the contaminants found in 77373.
| Found in 77373 | Water softener | AquaCarb PRO / ELITE | PureGuard RO / PureGuard ULTRA |
|---|---|---|---|
| Hardness (1.8–9.2 grains per gallon) | ✓ | – | ✓ |
| Arsenic | – | – | ✓ |
| Bromodichloromethane | – | ✓ | ✓ |
| Bromoform | – | ✓ | ✓ |
| Dichloroacetic acid | – | ✓ | ✓ |
| Gross alpha radioactivity | – | – | ✓ |
| Lead (home tap samples) | – | – | ✓ |
| Radium (combined 226 + 228) | ✓ | – | ✓ |
| Haloacetic acids (HAA5) | – | ✓ | ✓ |
| Iron | ✓ | – | – |
| Manganese | ✓ | – | – |
| Sodium | – | – | ✓ |
| Total dissolved solids (TDS) | – | – | ✓ |
| Total trihalomethanes (TTHMs) | – | ✓ | ✓ |
That is why our SENTINEL packages pair a whole-home system with a PureGuard RO & PureGuard ULTRA drinking water system. The softener and AquaCarb handle the water that goes on you. Reverse osmosis handles the water that goes in you. Salt delivery and filter changes are covered by the UnitedCare Membership.
About This Report
Test results come from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, covering samples collected October 2023 through October 2026. Legal limits and health goals are from the U.S. Environmental Protection Agency's National Primary and Secondary Drinking Water Regulations. "Average found" is the average of samples where the contaminant was detected.
Utility reports show the water the utility delivers. What comes out of your tap also depends on your home's plumbing. Lead and copper results come from samples taken at customers' taps. The best way to know what is in your water is to test it at your sink. We do that for free.
Every utility listed here is required to meet federal standards, and finding a contaminant above a health goal does not mean a utility is out of compliance.