ZIP 77449 Tap Water Quality Report
What the State of Texas found in the water utilities serving 77449 in Katy, TX, and how to treat it.
Found Above EPA Health Goals
An EPA health goal is the level at which no health risk is expected. Legal limits are often higher, because they also weigh the cost of treatment. These contaminants were found above the health goal in at least one utility serving 77449.
Source: Test results from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, samples collected October 2023 through October 2026. Health goals and legal limits from the U.S. EPA National Primary Drinking Water Regulations. Each utility below lists its state water system ID so you can look up its records.
Results by Water Utility
Your water utility is the name on your water bill. Open it to see everything the state found in its water from October 2023 through October 2026.
Harris County MUD 165 serves about 30,483 people · hardness 4.8 gpg (moderately hard) · 9 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 3 ppb | 3.3 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 4.3 ppb | 8.2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.2 ppb | 1.3 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 14.2 ppb | 39 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 5.1 pCi/L | 5.6 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 2.4 ppb | 8 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.5 pCi/L | 1.5 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-228 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1 pCi/L | 1 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Uranium Above health goal A naturally radioactive metal in Texas groundwater. | 1.6 ppb | 2.2 ppb | 30 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.2 ppb | 0.45 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.14 ppm | 0.16 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 2.9 ppb | 5.8 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 49.9 ppm | 77.2 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 10.6 ppb | 31.5 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.03 ppm | 0.57 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Cyanide From industrial discharge and some natural sources. | 30 ppb | 30 ppb | 200 ppb | 200 ppb | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.7 ppb | 2 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.8 ppb | 3.4 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.34 ppm | 0.75 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 19.3 ppb | 56.1 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.11 ppm | 1.3 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.013 ppm | 0.08 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 5.1 ppb | 5.1 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.6 ppb | 1.8 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.42 ppm | 0.67 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Nitrate + nitrite From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.4 ppm | 0.46 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Simazine A weed killer that runs off fields and roadsides. | 0.16 ppb | 0.25 ppb | 4 ppb | 4 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 87.2 ppm | 164 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 23.1 ppm | 38.3 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 308 ppm | 562 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 19.3 ppb | 41.2 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 5.4 ppb | 12 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.047 ppm | 0.047 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): 2,4-D, Butylated Hydroxytoluene, Texas Lead, Hexadecanoic Acid, Octadecanoic Acid, Erucylamide.
Source: TCEQ Drinking Water Viewer, public water system ID TX1012187. 323 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1012187.
Harris County MUD 71 serves about 16,917 people · hardness 3.8 gpg (moderately hard) · 6 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 6.8 ppb | 7.8 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 4.3 ppb | 6.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 4.9 ppb | 19 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 3.9 pCi/L | 3.9 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 6.4 ppb | 25.1 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.5 pCi/L | 1.5 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.17 ppm | 0.22 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 166 ppm | 280 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.4 ppb | 1.4 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.075 ppm | 0.27 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 4.8 ppb | 18 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.82 ppm | 1 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.14 ppm | 0.14 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0067 ppm | 0.0091 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.06 ppm | 0.06 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 185 ppm | 250 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 13.5 ppm | 16 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 549 ppm | 705 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 1.8 ppb | 2.2 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.014 ppm | 0.014 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Alkalinity, Carbonate, Xylenes, Total, Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1011823. 127 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1011823.
Harris County MUD 167 serves about 15,837 people · hardness 4.9 gpg (moderately hard) · 7 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 4.3 ppb | 5.2 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.6 ppb | 2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.7 ppb | 2.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 3 pCi/L | 3 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 7.8 pCi/L | 7.8 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 0.64 ppb | 0.9 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Uranium Above health goal A naturally radioactive metal in Texas groundwater. | 11.4 ppb | 11.4 ppb | 30 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.14 ppm | 0.17 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 57 ppm | 66 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 1.4 ppb | 1.4 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.043 ppm | 0.18 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.7 ppb | 3.5 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.7 ppm | 1.1 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.037 ppm | 0.044 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0029 ppm | 0.0043 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 99.3 ppm | 136 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 15 ppm | 15 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 359 ppm | 419 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 5.2 ppb | 9.6 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1012842. 61 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1012842.
Harris County Municipal Utility District 105 serves about 14,151 people · hardness 7.8 gpg (hard) · 7 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 7.5 ppb | 8.7 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 6.1 ppb | 7.2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 30.4 ppb | 30.4 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 2 pCi/L | 2 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 4.3 pCi/L | 4.4 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 1.9 ppb | 6.6 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Uranium Above health goal A naturally radioactive metal in Texas groundwater. | 3.1 ppb | 3.1 ppb | 30 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.16 ppb | 0.18 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.17 ppm | 0.23 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 7.5 ppb | 7.5 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 45.3 ppm | 49 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 15.7 ppb | 19.2 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.064 ppm | 0.34 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Cyanide From industrial discharge and some natural sources. | 113 ppb | 150 ppb | 200 ppb | 200 ppb | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.7 ppb | 1.7 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.6 ppb | 1.9 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.18 ppm | 0.19 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 40.1 ppb | 40.1 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.058 ppm | 0.058 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0025 ppm | 0.0026 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.5 ppb | 1.9 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.42 ppm | 1 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Simazine A weed killer that runs off fields and roadsides. | 0.075 ppb | 0.08 ppb | 4 ppb | 4 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 33.3 ppm | 35.3 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 17.7 ppm | 34 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 259 ppm | 271 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 28 ppb | 28 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 8 ppb | 8 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.033 ppm | 0.033 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1011227. 87 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1011227.
Harris County MUD 157 serves about 12,087 people · hardness 5.1 gpg (moderately hard) · 4 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 7 ppb | 13.3 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.8 ppb | 2.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 17.8 ppb | 36.7 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 5.9 ppb | 22 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Aluminum Can discolor water. | 0.037 ppm | 0.056 ppm | 0.2 guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.14 ppb | 0.23 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.052 ppm | 0.064 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 5.6 ppb | 9.4 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 39.3 ppm | 43 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 14 ppb | 32 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.029 ppm | 0.19 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.7 ppb | 3 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2.4 ppb | 6 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.2 ppm | 0.2 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 24.3 ppb | 51.5 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Manganese Causes black staining and a bitter taste. | 0.0053 ppm | 0.0059 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 2.4 ppb | 2.4 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.5 ppb | 1.9 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.64 ppm | 0.72 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Simazine A weed killer that runs off fields and roadsides. | 0.1 ppb | 0.13 ppb | 4 ppb | 4 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 32.6 ppm | 34.5 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 19.3 ppm | 30 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 194 ppm | 215 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 24.5 ppb | 41.9 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 5.5 ppb | 13.3 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.0069 ppm | 0.0069 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Methyl Isobutyl Ketone, Hexadecanoic Acid.
Source: TCEQ Drinking Water Viewer, public water system ID TX1011430. 119 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1011430.
Northwest Harris County Municipal Utility District 12 serves about 7,839 people · hardness 5.7 gpg (moderately hard) · 9 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 2.9 ppb | 3.7 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 2.6 ppb | 4.2 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 2.5 ppb | 3.5 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 8 pCi/L | 8 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Gross beta radioactivity Above health goal Radioactivity from natural and man-made sources. | 4.1 pCi/L | 4.1 pCi/L | 50 screening level (pCi/L) | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 3.7 ppb | 33.6 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.5 pCi/L | 1.5 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-226 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.5 pCi/L | 1.5 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Uranium Above health goal A naturally radioactive metal in Texas groundwater. | 6.9 ppb | 6.9 ppb | 30 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.13 ppm | 0.2 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 46.8 ppm | 50.5 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.057 ppm | 0.26 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 3.3 ppb | 6.1 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.38 ppm | 0.57 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.5 ppm | 1.4 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.015 ppm | 0.026 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.18 ppm | 0.18 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Selenium A natural mineral that is harmful at high levels. | 5 ppb | 5 ppb | 50 ppb | 50 ppb | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 93.6 ppm | 171 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 8 ppm | 10.1 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 368 ppm | 540 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 3.5 ppb | 3.5 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.012 ppm | 0.012 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Hardness, Calcium Magnesium, Alkalinity, Carbonate, Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1011901. 134 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1011901.
Harris County Municipal Utility District 449 serves about 7,179 people · hardness 4.6 gpg (moderately hard) · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 5.8 ppb | 6.6 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 1.1 ppb | 1.1 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 2.3 ppb | 2.6 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.15 ppm | 0.16 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 80.5 ppm | 85 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.014 ppm | 0.049 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.2 ppb | 1.4 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.51 ppm | 0.62 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.17 ppm | 0.24 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0083 ppm | 0.013 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 125 ppm | 132 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 18 ppm | 23 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 435 ppm | 441 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1013372. 66 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1013372.
Weston Municipal Utility District serves about 6,699 people · hardness 7.6 gpg (hard) · 6 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 6.2 ppb | 7 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1 ppb | 1 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Gross alpha radioactivity Above health goal Natural radioactivity from uranium and radium in groundwater. | 4.6 pCi/L | 4.6 pCi/L | 15 pCi/L | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 0.55 ppb | 0.6 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Radium (combined 226 + 228) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.2 pCi/L | 1.2 pCi/L | 5 pCi/L | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Radium-226 (part of combined radium) Above health goal Naturally radioactive. Long-term exposure is linked to cancer. | 1.2 pCi/L | 1.2 pCi/L | 5 combined (pCi/L) | Zero | Water softener PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.19 ppm | 0.2 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 65.5 ppm | 67 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.039 ppm | 0.13 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.37 ppm | 0.44 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.02 ppm | 0.023 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Nickel A natural metal. No federal limit. | 1.2 ppb | 1.3 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 69.1 ppm | 71.9 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 19 ppm | 19 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 333 ppm | 347 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 1 ppb | 1 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Also detected (no federal limit or health goal): Gross Alpha, Incl. Radon & U.
Source: TCEQ Drinking Water Viewer, public water system ID TX1010634. 50 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1010634.
Harris County Municipal Utility District 64 serves about 5,883 people · hardness 8.7 gpg (hard) · 3 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 3.5 ppb | 3.5 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1.6 ppb | 1.6 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 7.5 ppb | 19 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.16 ppm | 0.16 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 42 ppm | 42 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.068 ppm | 0.41 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 1.1 ppb | 1.2 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.2 ppm | 0.2 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.18 ppm | 0.18 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.016 ppm | 0.016 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 49.9 ppm | 49.9 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 16 ppm | 16 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 285 ppm | 285 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 2.8 ppb | 2.8 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1011513. 35 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1011513.
Harris County Municipal Utility District 239 serves about 5,583 people · hardness 3.6 gpg (moderately hard) · 2 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Arsenic Above health goal Occurs naturally in Texas groundwater. Long-term exposure is linked to cancer and to skin and circulatory problems. | 4.8 ppb | 4.8 ppb | 10 ppb | Zero | PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 3.2 ppb | 5.6 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.13 ppm | 0.13 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 50 ppm | 50 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.084 ppm | 0.67 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Cyanide From industrial discharge and some natural sources. | 90 ppb | 90 ppb | 200 ppb | 200 ppb | PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.84 ppm | 0.84 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Iron Causes rust stains and a metallic taste. | 0.1 ppm | 0.1 ppm | 0.3 taste/stain guideline (ppm) | None set | Water softener |
| Manganese Causes black staining and a bitter taste. | 0.0046 ppm | 0.0046 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 116 ppm | 116 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 13 ppm | 13 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 373 ppm | 373 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1012392. 37 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1012392.
West Harris County Municipal Utility District 7 serves about 5,467 people · hardness 10.3 gpg (hard) · 0 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Barium A natural metal. High levels can raise blood pressure. | 0.19 ppm | 0.19 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 50 ppm | 50 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.16 ppm | 0.16 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 1.8 ppb | 1.8 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.16 ppm | 0.16 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 34.3 ppm | 34.3 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 5 ppm | 5 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 293 ppm | 293 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Zinc Can give water a metallic taste. | 0.01 ppm | 0.01 ppm | 5 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1012228. 35 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1012228.
Harris County Municipal Utility District 127 serves about 5,147 people · hardness 6.1 gpg (moderately hard) · 4 above health goals
| Contaminant | Average found | Highest found | Legal limit | EPA health goal | Removed by |
|---|---|---|---|---|---|
| Bromodichloromethane Above health goal A trihalomethane disinfection byproduct. | 7.2 ppb | 9.7 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Bromoform Above health goal A trihalomethane disinfection byproduct. | 1 ppb | 1 ppb | part of TTHMs | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dichloroacetic acid Above health goal A haloacetic acid disinfection byproduct. | 18.5 ppb | 59.4 ppb | part of HAA5 | Zero | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Lead (home tap samples) Above health goal No safe level for children. Lead usually comes from household plumbing and fixtures, not the utility. | 7.6 ppb | 28 ppb | 15 action level (ppb) | Zero | PureGuard RO & PureGuard ULTRA |
| Atrazine A weed killer that runs off farm fields. | 0.14 ppb | 0.2 ppb | 3 ppb | 3 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Barium A natural metal. High levels can raise blood pressure. | 0.047 ppm | 0.047 ppm | 2 ppm | 2 ppm | Water softener PureGuard RO & PureGuard ULTRA |
| Bromochloroacetic acid A haloacetic acid disinfection byproduct. | 5 ppb | 7.8 ppb | None | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Chloride Gives water a salty taste. | 38 ppm | 38 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Chloroform A trihalomethane disinfection byproduct. | 14.1 ppb | 39.3 ppb | part of TTHMs | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Copper (home tap samples) Usually comes from household copper plumbing. | 0.032 ppm | 0.15 ppm | 1.3 action level (ppm) | 1.3 ppm | PureGuard RO & PureGuard ULTRA |
| Dibromoacetic acid A haloacetic acid disinfection byproduct. | 1.7 ppb | 2.1 ppb | part of HAA5 | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Dibromochloromethane A trihalomethane disinfection byproduct. | 2.6 ppb | 3.7 ppb | part of TTHMs | 60 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Fluoride Natural or added by the utility. Very high levels can affect teeth and bones. | 0.18 ppm | 0.18 ppm | 4 ppm | 4 ppm | PureGuard RO & PureGuard ULTRA |
| Haloacetic acids (HAA5) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 24.8 ppb | 72.5 ppb | 60 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Manganese Causes black staining and a bitter taste. | 0.0031 ppm | 0.0031 ppm | 0.05 taste/stain guideline (ppm) | None set | Water softener |
| Monochloroacetic acid A haloacetic acid disinfection byproduct. | 8.8 ppb | 8.8 ppb | part of HAA5 | 70 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Nickel A natural metal. No federal limit. | 2.2 ppb | 2.2 ppb | None | None set | Water softener PureGuard RO & PureGuard ULTRA |
| Nitrate From fertilizer, septic systems and natural deposits. High levels are dangerous for infants. | 0.87 ppm | 1.2 ppm | 10 ppm | 10 ppm | PureGuard RO & PureGuard ULTRA |
| Simazine A weed killer that runs off fields and roadsides. | 0.097 ppb | 0.11 ppb | 4 ppb | 4 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Sodium No federal limit. EPA advises 20 ppm or less for people on low-sodium diets. | 30.5 ppm | 30.5 ppm | None | None set | PureGuard RO & PureGuard ULTRA |
| Sulfate Can give water a bitter taste. | 37 ppm | 37 ppm | 250 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total dissolved solids (TDS) Everything dissolved in the water. High TDS affects taste. | 244 ppm | 244 ppm | 500 taste guideline (ppm) | None set | PureGuard RO & PureGuard ULTRA |
| Total trihalomethanes (TTHMs) Disinfection byproducts that form when chlorine reacts with organic matter. Long-term exposure is linked to cancer. | 23.7 ppb | 46.9 ppb | 80 ppb | None set | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
| Trichloroacetic acid A haloacetic acid disinfection byproduct. | 5.1 ppb | 13.1 ppb | part of HAA5 | 20 ppb | AquaCarb PRO & AquaCarb ELITE PureGuard RO & PureGuard ULTRA |
Source: TCEQ Drinking Water Viewer, public water system ID TX1012229. 54 samples tested October 2023 through October 2026. To see the state records yourself, open the TCEQ Drinking Water Viewer ↗, choose Water Systems and search for TX1012229.
How We Treat Katy Water
This is what each of our systems does about the contaminants found in 77449.
| Found in 77449 | Water softener | AquaCarb PRO / ELITE | PureGuard RO / PureGuard ULTRA |
|---|---|---|---|
| Hardness (3.6–10.3 grains per gallon) | ✓ | – | ✓ |
| Arsenic | – | – | ✓ |
| Bromodichloromethane | – | ✓ | ✓ |
| Bromoform | – | ✓ | ✓ |
| Dichloroacetic acid | – | ✓ | ✓ |
| Gross alpha radioactivity | – | – | ✓ |
| Gross beta radioactivity | – | – | ✓ |
| Lead (home tap samples) | – | – | ✓ |
| Radium (combined 226 + 228) | ✓ | – | ✓ |
| Uranium | – | – | ✓ |
| Haloacetic acids (HAA5) | – | ✓ | ✓ |
| Iron | ✓ | – | – |
| Manganese | ✓ | – | – |
| Sodium | – | – | ✓ |
| Total dissolved solids (TDS) | – | – | ✓ |
| Total trihalomethanes (TTHMs) | – | ✓ | ✓ |
That is why our SENTINEL packages pair a whole-home system with a PureGuard RO & PureGuard ULTRA drinking water system. The softener and AquaCarb handle the water that goes on you. Reverse osmosis handles the water that goes in you. Salt delivery and filter changes are covered by the UnitedCare Membership.
About This Report
Test results come from the Texas Commission on Environmental Quality (TCEQ) Drinking Water Viewer, covering samples collected October 2023 through October 2026. Legal limits and health goals are from the U.S. Environmental Protection Agency's National Primary and Secondary Drinking Water Regulations. "Average found" is the average of samples where the contaminant was detected.
Utility reports show the water the utility delivers. What comes out of your tap also depends on your home's plumbing. Lead and copper results come from samples taken at customers' taps. The best way to know what is in your water is to test it at your sink. We do that for free.
Every utility listed here is required to meet federal standards, and finding a contaminant above a health goal does not mean a utility is out of compliance.